1. How to Set Connection
In order to control your device with Relay Timer R1X,
be sure
to connect NCD relay board with your computer and connect your device with NCD 1-channel relay board at first, then set the connection as below.
Click
button on the interface.
The Configuration dialog will be shown.
Select the type of the reay board.
Select the type of connection.
Click OK to finish setting.
Back to Relay Timer R1X homepage
2. How to Turn On/Off Relay Manually
The light on top right of relay control panel indicates the status of the relay.
Red is for relay off. Green is for relay on.
Click
button down
to step into manual
operation mode.
Click the switch
to turn on the relay. The light becomes green.
Click the switch
to turn off the relay. The light becomes red.
Back to Relay Timer R1X homepage
3. How to Turn On/Off Relay Automatically
Click
button down
to step into auto mode.
To control relay automatically, the schedule of relay status must be set at first.
Click button on the relay control panel to open Relay
Setting dialog.
The relay can be given a name here.
Click Add button to open Schedule Setting dialog.
Edit the Schedule Name, select Relay Status,
set Schedule Time, select Recurrence Pattern
and Range .
Click OK to return Relay Setting dialog.
Different schedules can be added by this way.
Click OK to finish relay setting.
The relay will be turned on/off automatically according to the schedule list.
Back to Relay Timer R1X homepage
4. How to Customize Relay Status
The status of the relay can be customized except only on or off
during the setting time.
For example, relay can be on 10 minutes, off 5 minutes within one hour, and on 20 minutes and off 10 minutes within the other one hour. This can be set as steps below.
Step1. Click button on the Relay Control Panel to open Relay Setting dialog.
Step 2. Click Add button to open Schedule Setting dialog.
Edit the Schedule Name, set Schedule Time(2 hours), select Recurrence Pattern and Range .
Step 3. Click Customize Action or the edit button beside it to openCustomize Action dialog.
Step 4. Click Add button to open Add Actcion dialog.
Set Turn On 10 minutes, Turn Off 5 minutes and Loop Count 4.
Click OK to return Customize Action dialog. The action will be shown in the list.
Step 5. Click Add button to open Add Actcion dialog again.
Set Turn On 20 minutes, Turn Off 10 minutes and Loop Count 2.
Click OK to return Customize Action dialog. The action will also be shown in the list.
Click OK button to return Schedule Setting dialog and then return to Relay Setting dialog.
Click OK to finish relay setting.
The relay will be turned on/off automatically according to the customized setting.
Back to Relay Timer R1X homepage
5. How to Launch with Command Line
Relay Timer R1X can be run from command line with a specified
configuration or schedule setting file.
Format:
"Path to RelayTimer.exe" -c "Path to *.cfg"
"Path to RelayTimer.exe" -s "Path to *.sch"
Note:
The parameter "-c" is to launch Relay Timer R1X with the specified configuration
file (*.cfg). Both the contents in Configuration dialog and
Relay Setting dialog will be loaded. If the *.cfg file does not
exist, it will be created in the specified path automatically. After editing the
Configuration dialog and Setting dialogs, the information will be saved to the
created *.cfg file. When the command is run next time, all information will be
loaded automatically.
The parameter ''-s'' is to launch Relay Timer R1X with the schedule setting
file (*.sch). The content of
Relay Setting dialog will be loaded. All information will be saved in
the default configuration file. When Relay Timer R1X is launched by
Icon on desktop or start menu, it loads the default configuration file. When you
run this command, you need make sure the current default configuration file is
same as when the *.sch file was saved.
Example I:
Example II:
Back to Relay Timer R1X homepage
6. How to Control Relay Remotely
Relay Timer R1X can be controlled remotely from other computers.
Click Configure button to show the Configuration dialog.
Select Enable Control Remotely
checkbox. Set the Port Number or keep default value 80.
Select Password to set password for
remote access.
Click OK to finish setting.
Relay Timer R1X can be controlled on the other computer by visiting the current
computer's IP address in internet browser.
If Port Number is 80, you just need to type the IP address in the browser, shown
as above.
If Port Number is modified, you need add the number after the IP address, shown
as below.
Back to Relay Timer R1X homepage
|